RuptureSeal NRS Series Backup Relief Valves

A stainless steel valve sitting on top of a metal base.

The RutureSeal NRS Series Backup Relief Valves include a non-fragmenting reverse-buckling solid metal rupture disk which mounts directly to the chiller’s existing rupture disk flange. Model NRS-2 Model NRS-3 Manuals & Documentation:   NRS-2 & NRS-3 Bid Specification  NRS-2 & NRS-3 Brochure  Performance Chart  NRS-2 Manual  NRS-3 Manual  NRS-2 Specifications  NRS-3 Specifications

Read More

RuptureSeal RS Series Backup Relief Valves

A picture of the side view of a valve.

The RuptureSeal RS Series Backup Relief Valves, with their patented collection trap, can be installed utilizing the chiller’s existing carbon rupture disk and thus can be installed without having to shut down the chiller or pull its refrigerant charge. Manuals & Documentation:   Model RS-2 Bid Spec Guide  Model RS-2 Brochure  Model RS-2 Performance Chart  Model…

Read More

Non-Condensables Purger MODEL HPP-4A-C3

A machine that is sitting on top of a table.

For  INDOOR APPLICATIONS.     The Model HPP-4A-C3 High Pressure Refrigerant Purger automatically removes non-condensables from systems utilizing R-12, R-134a, R-22, R-502, R114 and other refrigerants with similar pressure ranges. The Model HPP-4A-C3 is engineered to assure the highest efficiency in preventing refrigerant from escaping to the atmosphere when removing non-condensables. The Redi-Purge Model HPP-4A-C3 provides simple refrigerant…

Read More

Very High Pressure Refrigerant Recovery System Model RS-503/13-C3

A blue and silver machine with a box on top of it.

Operational Overview The Model RS-503/13-C3 microprocessor controlled very high pressure refrigerant recovery system is designed to recover a series of very high pressure refrigerants used in cascade refrigeration systems and environmental test chambers. The unit is ARI Certified and is the best solution for recovery of very high pressure refrigerants. The RS-503/13-C3 recovery unit is…

Read More

Portable Non-Condensables Service Purger MODEL PSP-LP-1B

Three propane tanks are sitting on a table.

Your Competitive Edge…Chillers can quickly become air-logged due to sudden leaks or during servicing.  OEM Purgers, especially high efficiency systems, require hours of purging to bring  the chiller fully back on line.When your customer demands that you get its air-logged chiller back on-line fast, Redi Control’s Service Purge is the only tool available.Redi Control’s Service…

Read More

PREVAC AquaPower

A picture of an old time machine with the words " cloud " written on it.

This unit is a permanently installed refrigerant pressure controlled system for idle R-11 & R-123 chillers that circulate heated water through the evaporator for:  1. Pressure sealing a chiller during idle periods to prevent chiller downtime, prevent refrigerant contamination and acid damage, and eliminate hard start-ups and improve reliability.  2. Push-button pressurization to enable service…

Read More

Redi-Purge Model PRG-113-C3 & C4

A picture of an air conditioner unit.

The Redi-Purge obtains and efficiency of .59 pounds of CFC per pound of air emission.  The Redi-Purge and Emission Collection Canister emits only     ** .0049 pounds of CFC per pound of air emission, and the Redi-Purge with the Cryoline Emission Collection Canister reaches    ** .00040 pounds of CFC per pound of air emission.  The Redi-Purge    **cost less…

Read More

Refrigerant Gas Monitoring Equipment

A black background with a white circle in the middle.

Genesis International’s SHERLOCK & WIZARD Refrigerant monitors and Equipment. The Genesis Sherlock Refrigerant Gas Monitors are designed to meet the ASHRAE 15-1994 Standard and Uniform Mechanical Codes. The SHERLOCK Monitors offer a variety of features and benefits that allow for customized installation, providing customers with refrigerant monitoring equipment that meets their individual needs. The Genesis SHERLOCK Refrigerant…

Read More

Continuous Refrigerant Dehydrator Model CD-120

A black pen with pink tape on it.

Model CD-120 is designed to rapidly dehydrate a chiller’s refrigeration charge (flooded evaporator). Although the primary function of the Continuous Dehydrator is to dehydrate (remove moisture) from a refrigerant charge it also removes acids and particulates. The Continuous Refrigerant Dehydrator operates without the need of either a mechanical or eductor pump. Operation is accomplished via…

Read More